+8618657514717
Fluke Passed CAT6A Shielded and Foiled (SFTP) Solid Network Cable

Fluke Passed CAT6A Shielded and Foiled (SFTP) Solid Network Cable

DC resistance (max): 4.8Ω/100m at 20°C
Mutual capactitance (max): 5.6nF/100m;
Unbalanced capacitance (max): 330pF/100m
Send Inquiry
Product Details of Fluke Passed CAT6A Shielded and Foiled (SFTP) Solid Network Cable

Product Introduction

Our aim is to provide customers with a full range of 23AWG Outdoor Cat6 Cable UTP 4Pairs, SAT50 TV Cable, 4 PairCAT5E LSOH COMMUNICATION CABLE and high-quality and thoughtful service. Since innovative and successful things have passed, we clearly recognize that we need to persevere if we want to continue to develop. We have rich experience in export. We always abide by the business philosophy of shaping ourselves, honesty and serving the society.

Conductor


Construction

Material

Nominal size

Inner conductor

Copper

Φ0.57mm

Insulation

Polyethylene PE

Φ0.92±0.03mm

Shield1

AL/Copper Foil

Shield2

Drain wire 0.5CCA/Copper/TC

Rip cord

Nylon Material(Available)

Outer sheath

PVC

Φ5.6±0.4mm


Characteristics


Frequency

Attenuation

Max

IL(max)

Next

(min)

PSNEXT

(min)

ELFEXT

Min.

PSACR-F

(min)

(MH)z

(dB/100m)

(dB/100M)

(dB)

(dB)

(dB/100m)

(dB/100m)

1

1.9

2.2

74.1

72.1

67.4

64.4

4

3.7

3.8

65.4

63.5

54.6

52.5

10

5.9

6.0

59.6

57.9

48.1

44.6

16

7.5

7.6

56.1

53.1

43.5

40.4

20

8.4

8.5

55.9

52.3

42.0

38.6

31.25

10.6

10.7

52.2

51.0

37.9

34.2

62.5

15.4

15.4

47.4

46.5

32

28.6

100

19.8

19.8

44.4

41.2

27.6

24.5

200

29.0

29.0

39.6

37.8

21.5

18.6

250

32.8

32.8

38.3

36.3

20

16.1


Application


1.Computer network cabling project

2.Broadband network communication

3.Digital ISDN and ATM 155Mbps network

4.Ethernet network

5.Audio and data transmission.


DC resistance (max)

4.8Ω/100m at 20°C

Mutual capactitance (max)

5.6nF/100m;

Unbalanced capacitance (max)

330pF/100m

Dielectric strength between conductors (min)

2.5kV/2s

Impedance

1-250MHz 100±15Ω

Differential phase delay (max)

45ns/100m

Operating temperature

-20~+60°C

Permitted bend radius

10 times diameter of the cable

We can normally fulfill our respected consumers with our great excellent, great value and good provider due to we're much more specialist and extra hard-working and do it in cost-effective way for Fluke Passed CAT6A Shielded and Foiled (SFTP) Solid Network Cable. We will continue to work hard, be determined to innovate, meet customer needs, and measure our success by customer success! With the joint efforts of leaders and employees, our company has been developing and expanding and has been on the rise in recent years.

Hot Tags: shielded CAT6 network cable, China, manufacturers, suppliers, factory, wholesale, custom, Vietnam, 0.14 Mm Al-mg Wire, Unshielded Security Alarm Cable, Satellite Monitor CCTV Camera Rg59, Coaixal Cable RG59 For Security Cable, Direct Burial RG6 Coaxial Cable, copper-clad SAT 703E Coaxial Cable

[[ProKeywords]]

SPEC DATA

Send Inquiry

Send a Message