+8618657514717
Shielded Fire Alarm Cable
video
Shielded Fire Alarm Cable

Shielded Fire Alarm Cable

Nominal voltage: 350V
Test voltage: 2000V
Temperature range: -10℃+80℃
Send Inquiry
Product Details ofShielded Fire Alarm Cable

Vietnam Shield Fire Alarm Cable For Fire Alarm Security System suppliers

Application:

Alarm cables are for use with fire monitoring/detection, fire alarm systems, smoke detectors, signaling, audio circuits, control circuits, fire protective circuits and security systems.

1

Technical Data:

Nominal voltage

350V

Insulation resistance

>150Mohm*km

Test voltage

2000V


<90 Ohm/km(0.22mmq)

Temperature range

-10℃+80℃

Conductor resistance

<38 Ohm/km(0.50mmq)

<25 Ohm/km(0.75mmq)

Radiation resistance

80Mrade


<142 Ohm/km(0.50mmq)

<59 Ohm/km(0.6mmq)

Min.bending radius

12*ø

Capacitance

con./cond.approx.130pf/m


Basic construction

Unit:mm Stranded or Solid


Mode

Item

MATERIAL

24awg

22awg

20awg

18awg

16awg

14awg

12awg

10awg


2c

Conductor O.D.

Copper

0.6/0.51

0.75/0.64

0.94/0.81

1.17/1.02

1.5/1.29

1.87/1.63

2.37/2.15

3/2.58

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

4.22

4.62

4.80

5.12

5.75

6.23

7.29

8.58


3c

Conductor O.D.

Copper

0.60

0.75

0.94

1.17

1.5

1.87

2.37

3.00

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

4.77

5.36

5.75

6.45

6.73

7.70

8.66

10.27


4c

Conductor O.D.

Copper

0.6/0.51

0.75/0.64

0.94/0.81

1.17/1.02

1.5/1.29

1.87/1.63

2.37/2.15

3/2.58

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

5.25

5.59

6.15

7.03

7.53

8.67

9.79

11.67


5c

Conductor O.D.

Copper

0.60

0.75

0.94

1.17

1.5

1.87

2.37

3.00

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

5.67

6.05

6.68

7.48

8.24

9.53

10.78

12.90


6c

Conductor O.D.

Copper

0.6/0.51

0.75/0.64

0.94/0.81

1.17/1.02

1.5/1.29

1.87/1.63

2.37/2.15

3/2.58

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

6.05

6.47

7.56

8.45

9.28

10.88

12.27

14.60


7c

Conductor O.D.

Copper

0.60

0.75

0.94

1.17

1.5

1.87

2.37

3.00

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

6.40

6.85

8.00

8.96

9.86

11.59

13.09

15.61


8c

Conductor O.D.

Copper

0.6/0.51

0.75/0.64

0.94/0.81

1.17/1.02

1.5/1.29

1.87/1.63

2.37/2.15

3/2.58

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

6.72

7.20

8.41

9.44

10.40

12.24

13.85

16.55


9c

Conductor O.D.

Copper

0.60

0.75

0.94

1.17

1.5

1.87

2.37

3.00

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

7.02

7.54

8.79

9.88

10.91

12.85

14.56

17.42


10c

Conductor O.D.

Copper

0.6/0.51

0.75/0.64

0.94/0.81

1.17/1.02

1.5/1.29

1.87/1.63

2.37/2.15

3/2.58

Dielectric O.D.

Fr PVC or LSZH

1.5

1.65

1.9

2.22

2.52

3.03

3.53

4.37

Drain wire

TC or AL wire

0.45

0.5

0.64

0.64

0.81

0.81

0.81

0.81

Shield

PET-AL Tape

0.05

0.05

0.05

0.05

0.05

0.05

0.05

0.05

Jacket O.D.

Fr PVC or LSZH

7.31

7.85

9.15

10.30

11.49

13.42

15.23

18.26

Resistance:20℃ DC Ohm/Km≤

93.8

59.1

36.4

21.4

13.5

8.45

5.31

3.34


2

Our Services

1. Any inquiry will be replied within 24 hours.


2. Professional manufacturer, 12 years manufacturing experience.


3. OEM/ODM available.


4. High quality, reasonable and competitive price, fast delivery time.


5. Good after-sales service.


1) All products go through strict internal quality inspection before packing.


2) All products will be packed well before shipment.


6. Faster delivery:

Sample order is in stock, mass production takes 5-7 days.

Hot Tags: shielded fire alarm cable, China, manufacturers, suppliers, factory, wholesale, custom, Vietnam, Shielded Fire Alarm Cable, Security Alarm Cable, UnShielded Fire Alarm Cable

Send Inquiry

(0/10)

clearall